VL series V 4 WP - a hybrid inverter features IP65 rated enclosure. IP65 water and dust resistance provide excellent protection under diverse climates. VL series V 4 WP hybrid inverter is able to install in areas that are likely to suffer from sand and water penetration. User-programmable priority for PV, battery, and grid; and more via software, suits your need for that point in time of day or night. It helps to manage self-consumption and reduce electricity bills.
| MODEL | VL series V 4 WP 6K | VL series V 4 WP 8K | |
| PHASE | 1-phase in/1-phase out | ||
| Maximum PV Input Power | 6500W | 8000W | |
| Rated Output Power | 6000VA/6000W | 8000VA/8000W | |
| Maximum Charging Power | 6000W | ||
| GRID-TIE OPERATION | |||
| PV INPUT (DC) | |||
| Nominal DC Voltage / Maximum DC Voltage | 550 VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | ||
| MPPT Voltage Range | 120 VDC ~ 450 VDC | ||
| Number of MPP Trackers/Max. Input Current | 1 / 30A | ||
| GRID OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240 VAC | ||
| Output Voltage Range | 184 – 264.5 VAC or 195.5 – 253 VAC or 184 – 264.4 VAC (Selectable) | ||
| Nominal Output Current | 26A | 34.7A | |
| Power Factor | > 0.99 | ||
| EFFICIENCY | |||
| Maximum Conversion Efficiency (DC/AC) | 95% | ||
| OFF-GRID OPERATION | |||
| AC INPUT | |||
| AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC / 180 VAC | ||
| Acceptable Voltage Range | 90 – 280 VAC or 170 – 280 VAC | ||
| Maximum AC Input Current | 40A | 60A | |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | ||
| PV INPUT (DC) | |||
| Maximum DC Voltage | 550 VDC | ||
| MPPT Voltage Range | 120VDC / 150 VDC | ||
| Number of MPP Trackers/Max. Input Current | 1 / 30A | 2 / 18A | |
| BATTERY Mode Output (AC) | |||
| Nominal Output Voltage | 220/230/240 VAC | ||
| Output Waveform | Pure Sine Wave | ||
| Efficiency (DC to AC) | 93% | ||
| HYBRID OPERATION | |||
| PV INPUT (DC) | |||
| Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | ||
| MPPT Voltage Range | 120 VDC ~ 450 VDC | ||
| Number of MPP Trackers/Max. Input Current | 1 / 30A | 2 / 18A | |
| Maximum DC Voltage | 550 VDC | ||
| GRID OUTPUT (AC) | |||
| Nominal Output Current | 26A | 34.7A | |
| Nominal Output Voltage | 220/230/240 VAC | ||
| Output Voltage Range | 184 – 264.5 VAC or 195.5 – 253 VAC or 184 – 264.4 VAC (Selectable) | ||
| AC INPUT | |||
| AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC / 180 VAC | ||
| Acceptable Voltage Range | 90 – 280 VAC or 170 – 280 VAC | ||
| Maximum AC Input Current | 40A | 60A | |
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240 VAC | ||
| Efficiency (DC to AC) | 93% | ||
| BATTERY & CHARGER | |||
| Nominal DC Voltage | 48 VDC | ||
| Maximum Charging Current | 120 A | ||
| Maximum Solar Charging Current | 120 A | ||
| Maximum AC Charging Current | 120 A | ||
| GENERAL | |||
| PHYSICAL | |||
| Dimension, D X W X H (mm) | 192 x 360 x 665 | ||
| Net Weight (kgs) | 22.5 | 32 | |
| INTERFACE | |||
| Parallel Function | Yes, 9 units | ||
| Communication Port | USB or RS-232/Dry Contact/RS485 | ||
| ENVIRONMENT | |||
| Operating Humidity | 0~95% RH (Non-condensing) | ||
| Operating Temperature | -25°C to 50°C | ||
| IP degree | IP65 | ||