With Ingress protection to IP65, VL series Solar WP 10kW - 15kW is suitable for use both in outdoor applications and indoor environments where atmospheric moisture and dust are present. Parallel operation max to 6 units for greater power and capacity, enables a power rating of up to 90kW. This makes it possible to create energy solutions for homes, offices, and small commercial building applications.
| MODEL | VL series Solar WP 10KW | VL series Solar WP 12KW | VL series Solar WP 15KW | |
| PHASE | 3-phase in/3-phase out | |||
| Maximum PV Input Power | 14500W | 16000W | ||
| Rated Output Power | 10000 W | 12000 W | 15000 W | |
| Maximum Charging Power | 10000 W | 12000 W | 15000 W | |
| GRID-TIE OPERATION | ||||
| PV INPUT (DC) | ||||
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 1000 VDC | |||
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | |||
| Number of MPP Trackers/Max. Input Current | 2 / A: 26A, B: 13A | 2 / A: 26A, B: 26A | ||
| MPP Voltage Range | 350 VDC ~ 950 VDC | |||
| Number of Strings Per MPP Tracker | A: 2, B: 1 | A: 2, B: 2 | ||
| GRID OUTPUT (AC) | ||||
| Output Frequency Range | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | |||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |||
| Output Voltage Range | 184 – 265 VAC per phase | |||
| Nominal Output Current | 14.5 A per phase | 17.4 A per phase | 21.7 A per phase | |
| Power Factor | 0.9 lag ~ 0.9 lead | |||
| EFFICIENCY | ||||
| Maximum Conversion Efficiency (DC/AC) | >96% | |||
| European Efficiency@ Vnominal | >95% | |||
| OFF-GRID OPERATION | ||||
| AC INPUT | ||||
| AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC per phase/180 VAC per phase | |||
| Acceptable Voltage Range | 170 – 290 VAC per phase | |||
| Maximum AC Input Current | 40 A | |||
| PV INPUT (DC) | ||||
| Maximum DC Voltage | 1000 VDC | |||
| Number of MPP Trackers/Max. Input Current | 2 / A: 26A, B: 13A | 2 / A: 26A, B: 26A | ||
| MPP Voltage Range | 350 VDC ~ 950 VDC | |||
| Maximum DC Power | 14500W | 16000W | 22500W | |
| Number of Strings Per MPP Tracker | A: 2, B: 1 | A: 2, B: 2 | ||
| BATTERY MODE OUTPUT (AC) | ||||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |||
| Output Waveform | Pure sine wave | |||
| Efficiency (DC to AC) | 91% | |||
| Output Frequency | 50 Hz / 60 Hz (auto sensing) | |||
| HYBRID OPERATION | ||||
| PV INPUT (DC) | ||||
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 14500 VDC | 720 VDC / 16000 VDC | 720 VDC / 22500 VDC | |
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | |||
| Number of MPP Trackers/Max. Input Current | 2 / A: 26A, B: 13A | 2 / A: 26A, B: 26A | ||
| MPP Voltage Range | 350 VDC ~ 950 VDC | |||
| Number of Strings Per MPP Tracker | A: 2, B: 1 | A: 2, B: 2 | ||
| GRID OUTPUT (AC) | ||||
| Nominal Output Current | 14.5 A per phase | 17.4 A per phase | 21.7 A per phase | |
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |||
| Output Frequency Range | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | |||
| Output Voltage Range | 184 – 265 VAC per phase | |||
| Power Factor range | 0.9 lag ~ 0.9 lead | |||
| AC INPUT | ||||
| AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC per phase/180 VAC per phase | |||
| Acceptable Voltage Range | 170 – 290 VAC per phase | |||
| Maximum AC Input Current | 40 A | |||
| BATTERY MODE OUTPUT (AC) | ||||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |||
| Efficiency (DC to AC) | 91% | |||
| Output Waveform | Pure sine wave | |||
| Output Frequency | 50 Hz / 60 Hz (auto sensing) | |||
| BATTERY & CHARGER | ||||
| Maximum Charging Current | 220 A | 250 A | 300 A | |
| Battery Voltage Range | 40 ~ 62 VDC | |||
| GENERAL | ||||
| PHYSICAL | ||||
| Dimension, D X W X H (mm) | 247 x 500 x 650 | 255 x 660 x 750 | ||
| Net Weight (kgs) | 42 | 75 | 78 | |
| IP protection | IP 65 | |||
| INTERFACE | ||||
| Communication Port | RS-232, RS-485, USB, CAN and Wi-Fi | |||
| Intelligent Slot | Optional for SNMP and Modbus cards | |||
| ENVIRONMENT | ||||
| Operating Humidity | 0 ~ 100% RH (Non-condensing) | |||
| Operating Temperature | -25 to 60°C, > 45°C power derating | |||
| Altitude | 0 ~ 1000 m** | |||