Thanks to the smart monitoring platform, MR Solar Energy Solutions full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier.





| Model | DS-4K-G06P3-EU-AM2-P1 | DS-5K-G06P3-EU-AM2-P1 | DS-6K-G06P3-EU-AM2-P1 | DS-7K-G06P3-EU-AM2-P1 | DS-8K-G06P3-EU-AM2-P1 | DS-10K-G06P3-EU-AM2-P1 | DS-12K-G06P3-EU-AM2-P1 | DS-15K-G06P3-EU-AM2-P1 |
| Input Side | ||||||||
| Max. DC Input Power(kW) | 5.2 | 6.5 | 7.8 | 9.1 | 10.4 | 13 | 15.6 | 19.5 |
| Max. DC Input Voltage (V) | 1100 | |||||||
| Start-up DC Input Voltage(V) | 140 | |||||||
| MPPT Operating Range(V) | 120~1000 | |||||||
| Max. DC Input Current(A) | 20+20 | 20+26 | ||||||
| Max. Short Circuit Current (A) | 30+30 | 30+39 | ||||||
No.of MPP Trackers | 2 | |||||||
| No.of Strings per MPP Tracker | 1+1 | 1+2 | ||||||
| Output Side | ||||||||
| Rated Output Power(kW) | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 15 |
| Max. Active Power(kW) | 4.4 | 5.5 | 6.6 | 7.7 | 8.8 | 11 | 13.2 | 16.5 |
Rated Output Voltage/Range (V) | 3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards) | |||||||
| Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |||||||
| Operating Phase | Three phase | |||||||
| Rated AC Grid Output Current(A) | 6.1/5.8 | 7.6/7.3 | 9.1/8.7 | 10.7/10.2 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 | 22.8/21.8 |
| Max. AC Output Current(A) | 6.7/6.4 | 8.4/8 | 10/9.6 | 11.7/11.2 | 13.4/12.8 | 16.7/16 | 20/19.2 | 25/24 |
| Output Power Factor | 0.8 leading to 0.8 lagging | |||||||
Total Harmonics Current Distortion (THDi) | <3% | |||||||
| DC Injection Current(mA) | <0.5% | |||||||
| Grid Frequency Range | 45~55 or 55~65 (Optional) | |||||||
| Efficiency | ||||
| Max.Efficiency | 98.2% | 98.2% | 98.3% | 98.5% |
| Euro Efficiency | 97.5% | |||
| MPPT Efficiency | >99% | |||
| Protection | ||
| DC Reverse-Polarity Protection | Yes | |
| AC Short Circuit Protection | Yes | |
| AC Output Overcurrent Protection | Yes | |
| Output Overvoltage Protection | Yes | |
| Insulation Resistance Protection | Yes | |
| Ground Fault Monitoring | Yes | |
| Islanding Protection | Yes | |
| Temperature Protection | Yes | |
| Integrated DC Switch | Yes | |
| Remote software upload | Yes | |
| Remote change of operating parameters | Yes | |
| Surge protection | DC Type II / AC Type II | |
| General Data | |
Cabinet Size (WxHxD mm) | 283×463×178 (Excluding connectors and brackets) |
| Weight(kg) | 11 |
| Topology | Transformerless |
| Internal Consumption | <1W (Night) |
| Running Temperature | -25 to +60℃, >45℃ Derating |
| Ingress Protection | IP65 |
| Noise Emission(Typical) | <45 dB |
| Cooling Concept | Free Cooling |
Permissible Altitude (m) | 4000 |
| Warranty | 5 years |
| Grid Connection Standard | IEC 61727, IEC 62116, EN 50549 |
| Operating Surroundings Humidity | 0-100% |
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Features | |
| Display | LCD1602 |
| Interface | RS485/RS232/Wifi/LAN |